Aqua2use Greywater Treatment Systems
The filtered greywater from a Aqua2use Greywater Treatment System can be stored in a tank, and then reused to flush your toilets, do your laundry and wash your car.
Filter up to 1000 Liter/day.260 gallons /day
Features of Aqua2use Greywater Systems
Aqua2use® greywater treatment system applied Matala® progressive filtration for both Mechanical filtration and Biological filtration plus UV-C disinfection. Treated greywater can be reuse for indoor-toilet flushing, laundry as well as outdoor garden irrigation!
Use your water twice!
Purify greywater for indoor and outdoor reuse!
save up to 130,000 litres (40,000 gallons) annually for an average family of four
Uniqueness of Aqua2use Greywater Treatment System
- Low power consumption: +/- 2kWh /KL produced
- No chemical & disinfectants added
- No new water needed for backwash
- Modern design easily integrates with the environment
- User friendly : process is automatic & self-maintaining
- Long lasting Matala filter media, no regular replacement needed
- Progressive biofilter: copes with fluctuating flows & different levels of pollution
How Aqua2use GWTS Works
Step 1: Collect
The Aqua2use GWTS diverts water from the laundry, wash basins, bath and shower.
Step 2: Filter
Aqua2use GWTS’s state of the art filter mats offer the best filtration available for greywater.
Step 3: Flourish
The filtered water is immediately treated and disinfected and held in a storage tank (not provided) ready to be reused for toilet flushing, laundry, car washing and everyday garden irrigation.
The Aqua2use Greywater Treatment system collects the domestic wastewater from your bath, shower, laundry, and hand wash basins. The treatment system then applies progressive filtration for both mechanical and biological filtration plus UV-C disinfection. Once the Greywater is treated and disinfected, it is held in a storage tank ready to be reused at any time for toilet flushing, laundry, car washing and everyday garden irrigation. It not only saves water, but also reduces the energy of transporting full amounts of wastewater to the sewage treatment plant. Your actions today determine how the world is going to be tomorrow!
I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Technical Components/functions of the Aqua2use Greywater System
Pre-Filtration
Progressive Depth Filtration, a step system, first filters out bigger and then smaller particles, catching 60% to 90% of the suspended solids. Grit, hair lint, sand, soap scum, and silt are taken out.
Buffer Chamber/ Active Sludge Treatment / Skimming
Buffering: Combining active sludge and foam separation. Traveling Skimmer “collects and rejects scum” , Sediment Purging.
Air water pump
Air transports the water without grinding the particles.
Second Sedimentation Process
This tank gathers the organic sediments that were produced during the active sludge process.
Two-Fold Biological Treatment
The water undergoes two stages of Matala® progressive 3-D biofiltration. The secondary biofiltration process is resilient against shock loads. There are additionally fixed biofilter skimmers. The rotating air spitter periodically clears the Matala® biofilter media of attached flock. This cleaning feature is built-in and can be auto-programmed.
UV Disinfection
After the two-stage biological treatment, the water flows through a stainless steel chamber UV-C system for disinfection.
Drainage
Each chamber has its own sludge collection and purging. The concentrated sludge and sediment is disposed of through the drainage chamber connected to the sewage or septic tank.
Control Panel
The electronic control panel contains programmable functions and operational settings, including self-cleaning, energy saving, and functional alarms.
Aqua2use Greywater System Dimensions
The dimensions of the Aqua2use GWTS2000 are in inches and mm respectively:
.
- Prefilter (GWDD)
- Length: 24″
- Width: 15″
- Height: 20″
- Prefilter (GWDD)
- Length: 590mm″
- Width: 370mm ″
- Height: 512mm″
- Treatment chambers
- Length: 77″
- Width: 26″
- Height: 71″
- Treatment chambers
- Length: 1950mm″
- Width: 650mm″
- Height: 1800mm″
- control System
- Length: 16″
- Width: 13″
- Height: 20″
- control System
- Length: 400mm″
- Width: 315mm″
- Height: 714mm″
Ari pump Diaphragm Kits