How GWTS Fulfills the Greywater Recycling for Indoor Usage ?  

How Aqua2use® GWTS fulfills the needs? -reuse for indoor and outdoor

1.Function criteria: to reduce the BOD, SS, Turbidity and disinfect.

2.Installation criteria : easy installation, can be installed outdoor or indoor, compact system.

3.Operation criteria : auto cleaning, low power consumption, silent operation, faults alarm.

4.Maintenance criteria : low maintenance frequency: inspection only once or twice per year (depending on the regulations)

5.Regulation criteria : effluent water quality on BOD, SS, Turbidity and E.coli.

Aqua2use® GWTS effluent water quality

Test results Matala® Aqua2use® Greywater Treatment System
(flow rate: 900 LPD)
NATA approved lab water tests - period 6months - Total 31 samples
    BOD SS E.Coli Turbidity pH Conduct.
    mg/L mg/L Orgs/
100ml
NTU pH units uS/cm
Aqua2use®
Effluen
average < 3 < 2 < 1 0.47 7.9 497
max < 3 5 < 1 0.9 8.2 728
min < 3 < 2 < 1 0.3 7.6 324
Aqua2use®
Influent
max 666 110 220000 268 9.8 856
min 36 26 160 30 7.04 244
Technology brings you-
quality safe, user friendly with Modern design